Overview: .vishay. IHLP-2020BZ-11
Vishay Dale IHLP® mercial Inductors, Low DCR Series LINKS TO ADDITIONAL RESOURCES 3D 3D
3D Models Calculators STANDARD ELECTRICAL SPECIFICATIONS L0 INDUCTANCE HEAT ± 20 % DCR DCR RATING SATURATION AT 100 kHz, TYP. MAX. CURRENT CURRENT SRF 0.25 V, 0 A 25 °C 25 °C DC TYP. DC TYP. TYP. (μH) (mΩ) (mΩ) (A) (1) (A) (2) (MHz) 0.10 2.7 2.9 21.0 0.22 4.1 4.5 17.0 0.33 5.5 5.9 13.0 0.47 7.1 7.7 12.5 1.0 16.8 18.1 7.5 2.2 34.9 37.7 5.0 3.3 53.5 57.8 4.1 4.7 75.3 81.3 3.2 5.6 85.2 92.0 3.0 6.8 114.0 121.0 2.8 10.0 169.3 182.8 2.2 25.0 266 13.0 146 7.5 108 8.0 83 7.0 66 5.5 41 4.7 29 3.0 27 2.2 24 2.1 21 2.0 17 Notes
• All test data is referenced to 25 °C ambient
• Operating temperature range -55 °C to +125 °C
• The part temperature (ambient + temp. rise) should not exceed 125 °C under worst case operating conditions. Circuit design, ponent placement, PWB trace size and thickness, airflow and other cooling provisions all affect the part temperature. Part temperature should be verified in the end application.