• Part: MP-4
  • Description: Flammable Gas Sensor
  • Manufacturer: Winsen
  • Size: 501.66 KB
Download MP-4 Datasheet PDF
Winsen
MP-4
Features : - Lower consumption - Small size - Fast response and resume - Highest sensitivity - Excellent stability and long life - Easy circuit and big signal output - Excellent selectivity Application It is widely used in domestic gas leakage alarm, industrial flammable gas alarm and portable gas detector. Technical Parameters Model Sensor Type Standard Encapsulation Target Gas Detection range Standard Circuit Conditions Sensor character under standard test conditions Loop Voltage Heater Voltage Load Resistance Heater Resistance Heater consumption Sensitivity Sensitive resistance Vc VH RL RH PH S Concentration Slope α Tem. Humidity Standard test conditions Standard test circuit Preheat time MP-4 Flat surfaced Metal cap CH4, Nature gas 300-10000ppm ≤24V DC 5V±0.1V AC or DC Adjustable 85Ω±15Ω (room tem.) ≤350m W Ro(in air)/Rs(5000ppm CH4)≥5 1KΩ~20KΩ (in 5000ppm CH4) R /R≤0.6( 5000ppm 1000ppm CH4) 20℃±2℃;55%±5%RH Vc::5V±0.1V VH: 5V±0.1V Over 48 hours Tel:...