ITP0312S15 Datasheet Preview

ITP0312S15 Datasheet

DC-DC Converter

No Preview Available !

ITP Series
DC-DC Converter
3 Watts
xxx Series • Regulated single & dual outputs from 3.3 to 15VDC
• Wide 4:1 input range
• Input ranges 4.5 to 18, 9 to 36, 18 to 75VDC
• Ultra-compact SIP6 package
• 1.6kVDC input/output isolation
• High efficiency
• Complies with EN55032
• Short-circuit protection
• Remote On/Off (single output versions only)
• -40°C to +75°C operating temperature
• Full power to +70°C
• MTBF >0.95 Mhrs (MIL-HDBK-217F, +25°C GB)
• 3 year warranty
Dimensions:
ITP:
0.67 x 0.40 x 0.46” (17.0 x 10.1 x 11.7 mm)
The ITP series offers a compact 3W, cost effective DC-DC module with a wide range of input voltages and output voltages and regulation to 1%.
Industrial temperature range with a robust encapsulated construction.
Models & Ratings
Input Voltage
4.5-18 V
9-36 V
18-75 V
Output Voltage
3.3 V
5.0 V
12.0 V
15.0 V
±5.0 V
±12.0 V
±15.0 V
3.3 V
5.0 V
12.0 V
15.0 V
±5.0 V
±12.0 V
±15.0 V
3.3 V
5.0 V
12.0 V
15.0 V
±5.0 V
±12.0 V
±15.0 V
Output Current
(Full Load)
700 mA
600 mA
250 mA
200 mA
±300 mA
±125 mA
±100 mA
700 mA
600 mA
250 mA
200 mA
±300 mA
±125 mA
±100 mA
700 mA
600 mA
250 mA
200 mA
±300 mA
±125 mA
±100 mA
Notes
1. Input currents measured at nominal input voltage.
2. Maximum capacitive load is per output.
Input Current(1)
No Load
Full Load
45 mA
257 mA
45 mA
309 mA
50 mA
301 mA
55 mA
301 mA
40 mA
313 mA
50 mA
305 mA
60 mA
301 mA
25 mA
127 mA
25 mA
152 mA
35 mA
149 mA
35 mA
149 mA
30 mA
154 mA
35 mA
151 mA
40 mA
149 mA
15 mA
65 mA
15 mA
77 mA
15 mA
77 mA
20 mA
76 mA
15 mA
79 mA
20 mA
78 mA
30 mA
78 mA
Maximum
Capacitive Load(2)
3300 μF
1680 μF
820 μF
680 μF
±1000 μF
±470 μF
±330 μF
3300 μF
1680 μF
820 μF
680 μF
±1000 μF
±470 μF
±330 μF
3300 μF
1680 μF
820 μF
680 μF
±1000 μF
±470 μF
±330 μF
Efficiency
75%
81%
83%
83%
80%
82%
83%
76%
82%
84%
84%
81%
83%
84%
74%
81%
81%
82%
79%
80%
80%
Model Number
ITP0312S3V3
ITP0312S05
ITP0312S12
ITP0312S15
ITP0312D05
ITP0312D12
ITP0312D15
ITP0324S3V3
ITP0324S05
ITP0324S12
ITP0324S15
ITP0324D05
ITP0324D12
ITP0324D15
ITP0348S3V3
ITP0348S05
ITP0348S12
ITP0348S15
ITP0348D05
ITP0348D12
ITP0348D15
1
www.xppower.com




XP Power

ITP0312S15 Datasheet Preview

ITP0312S15 Datasheet

DC-DC Converter

No Preview Available !

ITP Series
DC-DC Converter
Input
Characteristic
Input Voltage Range
Input Filter
Input Reflected Ripple
Input Surge
Inhibit Mode Input Current
Output
Characteristic
Output Voltage
Initial Set Accuracy
Minimum Load
Line Regulation
Load Regulation
Cross Regulation
Transient Response Deviation
Ripple & Noise
Over Current Protection
Short Circuit Protection
Maximum Capacitive Load
Temperature Coefficient
Remote On/Off
Minimum
4.5
9
18
Capacitor
Typical
12
24
48
2.5
Maximum
18
36
75
Units
VDC
Notes & Conditions
ITP0312 series
ITP0324 series
ITP0348 series
20
mA pk-pk
Through 27 μH inductor and 47 μF capacitor
25
12 V models, ITP0312 series
50
VDC for 100 ms 24 V models, ITP0324 series
100
48 V models, ITP0348 series
mA
Measured by Vin nominal, when inhibited
Minimum
Typical
Maximum
Units
Notes & Conditions
3.3
30
VDC
See Models and Ratings table
±1
%
0
A
No minimum load required
±0.2
%
±1
%
From 0 to 100% load
±5
%
On dual output models when one load is varied between
25% and 100% and other is fixed at 100%
±5
% deviation Recovery time 500 μs, 25% load step change
150
Single Output. 20 MHz bandwidth. Measured using 0.1 μF
ceramic capacitor and 10 μF electrolytic capacitor
mV pk-pk
100
Dual Output. 20 MHz bandwidth. Measured using 0.1 μF
ceramic capacitor and 10 μF electrolytic capacitor
150
%
Overcurrent threshold
Continuous, with auto recovery
See Models and Ratings table
0.02
%/ ˚C
Output is on if Remote On/Off (pin 3) is open
Output turns off if 2-4 mA is applied to Remote On/Off (pin 3). Via 1kΩ resistor. Applies to single output models.
General
Characteristic
Efficiency
Isolation: Input to Output
Switching Frequency
Isolation Resistance
Isolation Capacitance
Power Density
Mean Time Between Failure
Case Material
Potting Material
Pin Material
Solder Process
Weight
Minimum
Typical
Maximum
Units
74
84
%
1600
VDC
100
kHz
109
Ω
40
pF
24
Win3
0.95
Mhrs
Non conductive black plastic
Epoxy (UL94V-0 rated)
C5191R-H Solder-coated
JEDEC J-STD 020D.1. 260 °C max. 1.5 mm from case 10s max.
0.008 (3.85)
lb (g)
Notes & Conditions
See Models and Ratings table
Functional
MIL-HDBK-217F, +25 °C GB
Environmental
Characteristic
Operating Temperature
Storage Temperature
Case Temperature
Humidity
Cooling
EMC: Emissions
Phenomenon
Conducted
Radiated
Minimum
-40
-55
Typical
Maximum
75
+125
+100
95
Units
°C
°C
°C
%RH
Notes & Conditions
Derate from 100% load at +70 °C to no load at +75 °C
Non-condensing
Natural convection
Standard
EN55032
EN55032
Test Level
Class A
Class A
Notes & Conditions
External components required. See application notes.
www.xppower.com
2


Part Number ITP0312S15
Description DC-DC Converter
Maker XP Power
PDF Download

ITP0312S15 Datasheet PDF






Similar Datasheet

1 ITP0312S12 DC-DC Converter
XP Power
2 ITP0312S15 DC-DC Converter
XP Power





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z



Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy