900,000+ datasheet pdf search and download

Datasheet4U offers most rated semiconductors data sheet pdf






Yokogawa

GP10 Datasheet Preview

GP10 Datasheet

Paperless Recorder

No Preview Available !

<<Contents>> <<Index>>
General
Specifications
GS 04L52B01-01EN
GP10/GP20
Paperless Recorder
(Portable type)
GX90XA/GX90XD/GX90YD I/O Modules
OVERVIEW
The GP10/GP20 are portable type paperless recorders
that display real-time measured data on a touch
screen and save data on an external storage medium
(SD card).
● The number of measurement data is a maximum
of 48 channels in GP10, and a maximum of 100
channels in GP20.
● The GP10/GP20 have the large internal memory
(GP10/GP20: 500MB), and prolonged record and
preservation are possible.
● As the input signal, a DC voltage, thermocouple,
resistance temperature detector, or contact signal
can be set to each channel.
● Input and output have module structure and it can
extend them easily. (GP10: max. 3, GP20: max. 10)
● A module type is three types, an analog input, a
digital input, and a digital output.
● The intuitive operation by flick, pinch in, pinch out,
and swipe are possible.
● The past trend under recording can be seamlessly
displayed on a trend screen.
● Moreover, the measurement data of the time
specified on the calendar screen can be searched
and displayed.
● Various functions, such as a freehand message,
a PDF/Excel output of a report file, a direct output
to a network printer, a scale movement of a trend
display, and a buzzer sound, are equipped.
● It can be hooked up to network via Ethernet, which
enables to inform by Email and to monitor on Web
site as well as to transfer files by using FTP. Also,
it can communicate with Modbus/RTU or Modbus/
TCP.
● A setup of GP can be performed on-line from the
web browser on PC. A setup by off-line is also
possible.
● Universal Viewer software allows a PC to
display waveforms on its screen and to print out
waveforms.
MAIN UNIT SPECIFICATIONS
■ FUNCTIONAL SPECIFICATION
Input Specifications
Please see "INPUT/OUTPUT MODULE
SPECIFICATIONS."
Display Functions
Display groups:
Number of groups; GP10: 30, GP20: 50
Number of channels that can be assigned to
each group; GP10: 10, GP20: 20
Scan interval: 100*, 200*, 500 ms*, 1, 2, 5 s
* Cannot be specified if an electromagnetic relay
scanner type (Type Suffix Code: -T1) analog input
module is in use.
GP10
GP20
Display color (Trend/Bar graph/Digital display):
Channel: Select from 24 colors
A desired display color can be selected freely
using its RGB value.
Background: Select from white or black
Display type:
● Trend display (T-Y)
Display method:
Direction: Horizontal, vertical
Trend interval: 5*, 10*, 15*, 30 s/div, 1, 2, 5,
10, 15, 20, 30 min/div, 1, 2, 4, 10 h/div
* Cannot be specified if an electromagnetic relay
scanner type analog input module is in use.
Trend line width: Thick, normal, thin
Scale; GP10: Max. 6, GP20: Max. 10
Current value bar graph, color scale band,
and alarm point marks can be displayed on
the scale.
Moving scale; Scale can be moved on any
waveform.
A bitmap image scale can be attached.
Others; Grid (Auto, 4 to 12), Trip line, Message,
Zone display, Partial expanded display
● Historical trend display (T-Y display)
Redisplays the display data or event data in the
internal memory or external storage medium
Time axis operation: The time axis can be
reduced or expanded.
Data search: Waveforms from the internal
memory can be displayed through the
specification of a date and time, calendar, each
summary
Moving scale; A bitmap image scale can be
attached.
All historical trends can be displayed in one
screen.
● Bar graph display
Direction: Vertical or horizontal
Scale: Display a scale for each channel
Color scale band, and alarm point marks can
be displayed on the scale.
Yokogawa Electric Corporation
2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan
GS 04L52B01-01EN
©Copyright Octorber 2012
7th Edition May. 7, 2013




Yokogawa

GP10 Datasheet Preview

GP10 Datasheet

Paperless Recorder

No Preview Available !

<<Contents>> <<Index>>
● Digital display
Displays measured values numerically
A DI input state can be displayed as an arbitrary
character string (0=Off/1=On, etc.)
Update rate: 0.5 s
● Overview display
Display format: All channels (GP10: Max. 30,
GP20: Max. 100), each groups
Displays the measured values of all channels
and the alarm statuses
● Alarm summary display
Displays a log of up to 1000 alarms
Specify an alarm with the cursor and jump to
the corresponding section on the historical trend
display.
● Message summary display
Time and content of up to 500 messages
(including 50 add messages)
Specify a message with the cursor and jump to
the corresponding section on the historical trend
display.
Memory summary display
Displays the information (up to 500) of the data
in the memory
Specify a file with the cursor and jump to the
corresponding section on the historical trend
display.
● Report display
Displays the report data residing in the internal
memory
For more details, see "MATHEMATICAL
FUNCTIONS WITH REPORT FUNCTION (/MT)."
● Log display
Displays the event log, error log, communication
log, FTP log, Web log, e-mail log, SNTP log,
DHCP log, and Modbus log.
● Multi-panel display
Divides the screen into two to six sections and
displays some different display formats.
● Other displays
Network information display
System information display
System configuration display
Auto scroll:
The displayed groups can be automatically
switched at a specified interval.
The display switches in ascending group order.
Names of channels:
XXXX
Channel number;
Analog input: 01 to 10
Digital input: 01 to 16
Digital output: 01 to 06
Slot number; GP10: 0 to 2, GP20: 0 to 9
Main unit: 0
Tags:
• Tag and Tag numbers can be displayed.
• Tag number; Number of characters: Up to 16
Displayable characters: Alphanumeric characters
Tag numbers can be enabled or disabled.
• Tag; Number of characters: Up to 32
Displayable characters: Alphanumeric characters
2
Message:
• Write messages to the trend display.
• Number of messages: 100
• Number of characters: Up to 32
• Write method: Write a preset message or write
an arbitrary message on the spot.
• Write destination: Select only the displayed
group or all groups.
• Auto message: Write a message when the GP
recovers from a power failure while memory
sampling is in progress.
Write a message when the trend interval is
switched during memory sampling.
Add message:
• Write messages to the past data positions.
• Message: The same as the “Message” item
above
Number of writable messages per file: 50
messages (including 10 freehand messages)
Freehand message:
• Can be written by dedicated pen.
Number of writable messages per file: 50
messages (including 10 Add messages)
Data Saving Functions
Internal memory:
• Temporarily saves various types of data.
• Medium: Flash memory
• File storage capacity; 500 MB
External storage medium:
• Medium SD card (SD/SDHC) (up to 32 GB)
• Format: FAT32 or FAT16
Data type:
• Display data, Event data, Alarm summary data,
Manual sampled data, Screen image data, Setup
data, and Report data
Display data:
• Target: Measurement (input/output module)/
math/communication channels, alarm summary,
message summary
Description: Maximum or minimum value per
recordling interval
• Recording intervals: Determined by the trend
interval
For GP20
Trend interval (div)
5s
Number of channels
100
10 s
15 s or longer
200
500
Note that the maximum number of channels is
fixed at 100 in the GP10.
• Data size;
Analog input data: 12 bytes/ch.
Digital I/O data: 4 bytes/ch.
Math channel data: 12 bytes/ch.
Communication channel data: 12 bytes/ch.
• File size: Up to 18 MB
• Number of files: Up to 500 (including event data)
• Operation in the internal memory: FIFO (First In
First Out)
• Data format: Binary or text
• Recording: Records data at all times.
All Rights Reserved. Copyright © 2012-2013, Yokogawa Electric Corporation
GS 04L52B01-01EN
May. 7, 2013-00


Part Number GP10
Description Paperless Recorder
Maker Yokogawa
Total Page 21 Pages
PDF Download

GP10 Datasheet PDF

View PDF for Mobile








Similar Datasheet

1 GP10 Paperless Recorder
Yokogawa
2 GP100 (GP100 - GP110) 1 AMP HIGH RELIABILITY SILICON DIODES
DIOTEC Electronics Corporation
3 GP100 PPTC Thermistors
Goodpoly
4 GP1001 Glass Passivated Rectifiers
Taiwan Semiconductor
5 GP1001-7R 120...195 Watt DC-DC Converters
Power-One
6 GP1002 Glass Passivated Rectifiers
Taiwan Semiconductor
7 GP1003 Glass Passivated Rectifiers
Taiwan Semiconductor
8 GP1004 Glass Passivated Rectifiers
Taiwan Semiconductor
9 GP1005 Glass Passivated Rectifiers
Taiwan Semiconductor





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy