SIB865170 Datasheet Preview

SIB865170 Datasheet

AC Semiconductor Contactor

No Preview Available !

celpac®
AC Semiconductor Contactor
pitch 45mm
compact size and DIN rail mounting.
t Ready to use Two-Phase Relay: " Install it & Forget it!"
t Zero cross model : 24-510VAC 50A
back to back thyristors on output -
TMS2 technology - I2t value > 1500A2s
t Large control range : 3,5-32VDC with each input
current < 10 mA on all the range.
Green LED visualization on the input.
t Very high immunity : Voltage protection on output
and input- 4kV according IEC61000-4-4 & 5
t IP20 housing
t Low leakage current (<1mA) and low zero cross
voltage .
t Mounting and dismounting on DIN rail without any
tool or directly mountable on panel.
t Designed in conformity with EN60947-4-3
(IEC947-4-3) and EN60950
-UL-cUL
http://www.DataSheet4U.net/
Dimensions :
S/CLP/SIB865170/B/21/04/2004
page 1 / 4GB
SIB865170
Output : 24-510VAC 2x22A(*)
2 Inputs : 3,5-32VDC / I<10mA
(*) see conditions (thermal curve page 3)
2 x18A
3x 400VAC
Proud to serve you
All technical caracteristics are subject to change without previous notice.
Caractéristiques sujettes à modifications sans préavis.
Protection
L1 L2
Typical
application:
12kW resistor
(AC-51 load)
on 400 VAC
The two input
control can be
mounted in
parallel or in serie
T1 T2
A2 A1
-+
Control
A2 A1
-+
Control
LOAD /CHARGE
celduc
relais
datasheet pdf - http://www.DataSheet4U.net/




celduc

SIB865170 Datasheet Preview

SIB865170 Datasheet

AC Semiconductor Contactor

No Preview Available !

celpac®
S/CLP/SIB865170/B/21/04/2004
page 2 / 4GB
Control characteristics (at 25°C)
for each input :
Two inputs can be mounted in parallel or in serie
DC
Input : Ic = f( Uc)
Paramètre / Parameter
Symbol Min Nom Max Unit 12
Control voltage
Uc 3,5 5-12-24 32 V
10
Control current (@ Uc )
Release voltage
Input LED
Reverse voltage
Ic <10 <10 <10 mA
Uc off 2
V
green
Urv 32 V
8
6
4
Clamping voltage
Uclamp
42
V2
Input immunity : EN61000-4-4
Input immunity : EN61000-4-5
2kV
2KV
0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32
Uc ( VDC)
Output characteristics (at 20°C)
Parameter for each way
Conditions
Symbol
Typ.
Unit
Load voltage
Ue 400 V rms
Operating range
Uemin-max
24-510
V rms
Peak voltage
Up
1200
V
Clamping voltage
Uclamp 820 (@1mA)
V
Zero cross level
Usync 20 V
Latching voltage
Ie nom Ua 8 V
AC-51 nominal current : permanent
( see Fig. 2 page 3) Ie AC-51
2 x 22
A rms
AC-53 nominal current
Ie AC-53
2 x 12
A rms
Non repetitive overload current
tp=10ms (Fig. 3)
Itsm
550 A
On state voltage drop (typical value)
@ 25°C Vt 0,9 V
Dynamic resistance (typical value)
rt 8 m
Output Power dissipation (typical value) : for each way ( ==> x2)
Pd 0,81xIe+0,08xIe2 W
Thermal resistance between junction to air
Off state leakage current
Minimum load current
Turn on time
Turn off time
Operating frequency range
Off state dv/dt
Maximum di/dt non repetitive
I2t (<10ms)
Conducted immunity level
Conducted immunity level
Short circuit protection
@Ue, 50Hz
http://www.DataSheet4U.net/
Uc nom DC ,f=50Hz
Uc nom DC ,f=50Hz
IEC 1000-4-4 (burst)
IEC 1000-4-5(schocks)
FERRAZ
Rthj/a
2,2 (1,8)
K/W
Ilk <1 mA
Iemin
5 mA
ton max
10
ms
toff max
10
ms
f
0,1-440
Hz
dv/dt
500 V/µs
di/dt 50 A/µs
I2t
1500
A2s
4kV criterion A
4kV criterion A
gRC 25A/32A/50A/63A 14x51
General characteristics (at 20°C)
Input to output insulation
Output to case insulation
Insulation resistance
Rated impulse voltage
Protection level / CEI529
Pollution degree
Vibration resistance 10 -55 Hz according to CEI68 :
Shocks resistance according to CEI68 ( on DIN rail / with screws)
Ambient temperature (with no icing or condensation)
Storage temperature (with no icing or condensation)
Ambient humidity
Weight
Conformity
Conformity
Ui
Ui
Ri
Uimp
-
-
double amplitude
-
-
HR
4000
4000
100 (@500VDC)
4000
IP20
2
1,5
30/50
-30 /+80
-30/+100
40 to 85
450
EN60947-4-3 (IEC947-4-3)
EN60950 UL/cUL pending
VRMS
VRMS
M
V
mm
g
°C
°C
%
g
celduc
relais
www.celduc.com
Rue Ampère B.P. 4
42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19
datasheet pdf - http://www.DataSheet4U.net/


Part Number SIB865170
Description AC Semiconductor Contactor
Maker celduc
PDF Download

SIB865170 Datasheet PDF





Similar Datasheet

1 SIB865170 AC Semiconductor Contactor
celduc





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy