900,000+ datasheet pdf search and download

Datasheet4U offers most rated semiconductors data sheet pdf






etcTI

CD74ACT05 Datasheet Preview

CD74ACT05 Datasheet

Hex Inverters

No Preview Available !

www.ti.com
FEATURES
Inputs Are TTL-Voltage Compatible
Speed of Bipolar F, AS, and S, With
Significantly Reduced Power Consumption
Fanout to 15 F Devices
SCR-Latchup-Resistant CMOS Process and
Circuit Design
Exceeds 2-kV ESD Protection Per
MIL-STD-883, Method 3015
CD54ACT05, CD74ACT05
HEX INVERTERS
WITH OPEN-DRAIN OUTPUTS
SCHS311C – JANUARY 2001 – REVISED JANUARY 2007
CD54ACT05 . . . F PACKAGE
CD74ACT05 . . . E OR M PACKAGE
(TOP VIEW)
1A
1Y
2A
2Y
3A
3Y
GND
1
2
3
4
5
6
7
14 VCC
13 6A
12 6Y
11 5A
10 5Y
9 4A
8 4Y
DESCRIPTION/ORDERING INFORMATION
The 'ACT05 devices contain six independent inverters. These devices perform the Boolean function Y = A. The
open-drain outputs require pullup resistors to perform correctly, and can be connected to other open-drain
outputs to implement active-low wired-OR or active-high wired-AND functions.
TA
–55°C to 125°C
PDIP – E
SOIC – M
CDIP – F
ORDERING INFORMATION
PACKAGE (1)
ORDERABLE PART NUMBER
Tube of 25
CD74ACT05E
Tube of 50
CD74ACT05M
Reel of 2500
CD74ACT05M96
Reel of 1000
CD54ACT05F3A
TOP-SIDE MARKING
CD74ACT05E
ACT05M
CD54ACT05F3A
(1) Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are available at
www.ti.com/sc/package.
FUNCTION TABLE
(EACH INVERTER)
INPUT
A
H
L
OUTPUT
Y
L
Z
AY
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas
Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2001–2007, Texas Instruments Incorporated
On products compliant to MIL-PRF-38535, all parameters are
tested unless otherwise noted. On all other products, production
processing does not necessarily include testing of all parameters.




etcTI

CD74ACT05 Datasheet Preview

CD74ACT05 Datasheet

Hex Inverters

No Preview Available !

CD54ACT05, CD74ACT05
HEX INVERTERS
WITH OPEN-DRAIN OUTPUTS
SCHS311C – JANUARY 2001 – REVISED JANUARY 2007
Absolute Maximum Ratings(1)
over operating free-air temperature range (unless otherwise noted)
www.ti.com
VCC Supply voltage range
IIK Input clamp current(2)
IOK Output clamp current(2)
IO Continuous current
θJA Package thermal impedance(3)
Tstg Storage temperature range
VI < 0 or VI > VCC
VO < 0
E package
M package
MIN MAX UNIT
–0.5 6 V
±20 mA
–50 mA
±50 mA
80
°C/W
86
–65 150 °C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The input and output negative voltage ratings may be exceeded if the input and output current ratings are observed.
(3) The package thermal impedance is calculated in accordance with JESD 51-7.
Recommended Operating Conditions(1)
VCC
VIH
VIL
VI
VO
IOL
t/v
Supply voltage
High-level input voltage
Low-level input voltage
Input voltage
Output voltage
Low-level output current
Input transition rise or fall rate
TA = 25°C
MIN MAX
4.5 5.5
2
0.8
0 VCC
0 5.5
24
10
–40°C TO
85°C
MIN MAX
4.5 5.5
2
0.8
0 VCC
0 5.5
24
10
–55°C TO
125°C
MIN MAX
4.5 5.5
2
0.8
0 VCC
0 5.5
24
10
UNIT
V
V
V
V
V
mA
ns/V
(1) All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
Electrical Characteristics
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
VOL
II
ICC
ICC
Ci
VI = VIH or VIL
VI = VCC or GND
VI = VCC or GND,
VI = VCC– 2.1 V
IOL = 50 mA
IOL = 24 mA
IOL = 50 mA(1)
IOL = 75 mA(1)
IO = 0
VCC
4.5 V
4.5 V
5.5 V
5.5 V
5.5 V
5.5 V
4.5 V to 5.5 V
TA = 25°C
MIN MAX
0.1
0.36
±0.1
4
2.4
10
–40°C TO
85°C
MIN MAX
0.1
0.44
1.65
±1
40
2.8
10
–55°C TO
125°C
MIN MAX
0.1
0.5
1.65
UNIT
V
±1 µA
80 µA
3 mA
10 pF
(1) Test one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage
to minimize power dissipation. Test verifies a minimum 50-transmission-line drive capability at 85°C and 75-transmission-line drive
capability at 125°C.
2 Submit Documentation Feedback


Part Number CD74ACT05
Description Hex Inverters
Maker etcTI
Total Page 14 Pages
PDF Download

CD74ACT05 Datasheet PDF

View PDF for Mobile








Similar Datasheet

1 CD74ACT00 QUADRUPLE 2-INPUT POSITIVE-NAND GATES
etcTI
2 CD74ACT02 QUADRUPLE 2-INPUT POSITIVE-NOR GATES
etcTI
3 CD74ACT04 HEX INVERTERS
etcTI
4 CD74ACT05 Hex Inverters
etcTI
5 CD74ACT08 QUADRUPLE 2-INPUT POSITIVE-AND GATES
etcTI





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy