Datasheet Summary
.ti.
SNVS785A
- JANUARY 2011
- REVISED APRIL 2013
LM25056A System Power Measurement IC with PMBus
Check for Samples: LM25056A
Features
- 234 Input Voltage Range: 3V to 17V
- I2C/SMBus Interface with PMBus pliant mand Structure
- Remote Temperature Sensing with Programmable Warning and Shutdown Thresholds
- Real Time Monitoring of VIN, IIN, PIN, VAUX with 12-bit Resolution and 1 kHz Sampling Rate
- Current Measurement Error: ±0.5%: +10°C to +85°C
- Voltage Measurement Error: ±1.0%: +10°C to+85°C
- Power Measurement Error: ±1.5%: +10°C to +85°C
- True Input Power Measurement Using Simultaneous Sampling of VIN and IIN Accurately Averages Dynamic Power Readings
-...