SN54ALS04B Datasheet Preview

SN54ALS04B Datasheet

Hex Inverters

No Preview Available !

SN54ALS04B, SN54AS04, SN74ALS04B, SN74AS04
HEX INVERTERS
Package Options Include Plastic
Small-Outline (D) Packages, Ceramic Chip
Carriers (FK), and Standard Plastic (N) and
Ceramic (J) 300-mil DIPs
description
These devices contain six independent hex
inverters. They perform the Boolean function
Y = A.
The SN54ALS04B and SN54AS04 are
characterized for operation over the full military
temperature range of − 55°C to 125°C. The
SN74ALS04B and SN74AS04 are characterized
for operation from 0°C to 70°C.
SDAS063B − APRIL 1982 − REVISED DECEMBER 1994
SN54ALS04B, SN54AS04 . . . J PACKAGE
SN74ALS04B, SN74AS04 . . . D OR N PACKAGE
(TOP VIEW)
1A 1
1Y 2
2A 3
2Y 4
3A 5
3Y 6
GND 7
14 VCC
13 6A
12 6Y
11 5A
10 5Y
9 4A
8 4Y
SN54ALS04B, SN54AS04 . . . FK PACKAGE
(TOP VIEW)
FUNCTION TABLE
(each inverter)
INPUT OUTPUT
A
Y
H
L
L
H
3 2 1 20 19
2A 4
18 6Y
NC 5
17 NC
2Y 6
16 5A
NC 7
15 NC
3A 8
14 5Y
9 10 11 12 13
logic symbol
1
1A
1
3
2A
5
3A
9
4A
11
5A
13
6A
2
1Y
4
2Y
6
3Y
8
4Y
10
5Y
12
6Y
This symbol is in accordance with ANSI/IEEE Std 91-1984
and IEC Publication 617-12.
Pin numbers shown are for the D, J, and N packages.
NC − No internal connection
logic diagram (positive logic)
1
1A
2
1Y
3
2A
4
2Y
5
3A
6
3Y
9
4A
8
4Y
11
5A
10
5Y
13
6A
12
6Y
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
Copyright 1994, Texas Instruments Incorporated
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
1
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443




etcTI

SN54ALS04B Datasheet Preview

SN54ALS04B Datasheet

Hex Inverters

No Preview Available !

SN54ALS04B, SN54AS04, SN74ALS04B, SN74AS04
HEX INVERTERS
SDAS063B − APRIL 1982 − REVISED DECEMBER 1994
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Operating free-air temperature range, TA: SN54ALS04B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −55°C to 125°C
SN74ALS04B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
VCC
VIH
Supply voltage
High-level input voltage
VIL
Low-level input voltage
IOH
High-level output current
IOL
Low-level output current
TA
Operating free-air temperature
Applies over − 55°C to 70°C temperature range
§ Applies over 70°C to 125°C temperature range
SN54ALS04B
MIN NOM MAX
4.5
5 5.5
2
0.8‡
0.7§
− 0.4
4
− 55
125
SN74ALS04B
MIN NOM MAX
4.5
5 5.5
2
0.8
UNIT
V
V
V
−0.4 mA
8 mA
0
70 °C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
SN54ALS04B
MIN TYP¶ MAX
SN74ALS04B
MIN TYP¶ MAX UNIT
VIK
VCC = 4.5 V,
II = −18 mA
−1.2
−1.2 V
VOH
VCC = 4.5 V to 5.5 V,
IOH = − 0.4 mA
VCC − 2
VCC − 2
V
VOL
VCC = 4.5 V
IOL = 4 mA
IOL = 8 mA
0.25 0.4
0.25 0.4
V
0.35 0.5
II
VCC = 5.5 V,
VI = 7 V
0.1
0.1 mA
IIH
VCC = 5.5 V,
VI = 2.7 V
20
20 µA
IIL
VCC = 5.5 V,
IO#
VCC = 5.5 V,
VI = 0.4 V
VO = 2.25 V
− 0.1
−0.1 mA
− 20
−112 −30
−112 mA
ICCH
VCC = 5.5 V,
VI = 0
0.65 1.1
0.65 1.1 mA
ICCL
VCC = 5.5 V,
VI = 4.5 V
2.9 4.4
2.9 4.2 mA
All typical values are at VCC = 5 V, TA = 25°C.
# The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS.
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443



Part Number SN54ALS04B
Description Hex Inverters
Maker etcTI
Total Page 3 Pages
PDF Download

SN54ALS04B Datasheet PDF





Similar Datasheet

1 SN54ALS04B Hex Inverters
etcTI





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy