TVS2200 - 22-V Flat-Clamp Surge Protection

Description

The TVS2200 robustly shunts up to 40 A of IEC 61000-4-5 fault current to protect systems from high power transients or lightning strikes.

Features

  • 1 Protection Against ±1 kV, 42 Ω IEC 61000-4-5 Surge Test for Industrial Signal Lines.
  • Max Clamping Voltage of 28.4 V at 40 A of 8/20 µs Surge Current.
  • Standoff Voltage: 22 V.
  • Tiny 4 mm2 Footprint.
  • Survives Over 5,000 Repetitive Strikes of 35 A 8/20 µs Surge Current at 125°C.
  • Robust Surge Protection:.
  • IEC 61000-4-5 (8/20 µs): 40 A.
  • IEC 61643-321 (10/1000 µs): 5 A.
  • Low Leakage Current.
  • 3.5 nA Typical at 27°C.

📥 Download Datasheet

Full PDF Text Transcription

Click to expand full text
Product Folder Order Now Technical Documents Tools & Software Support & Community TVS2200 SLVSED5A – DECEMBER 2017 – REVISED MARCH 2018 TVS2200 22-V Flat-Clamp Surge Protection Device 1 Features •1 Protection Against ±1 kV, 42 Ω IEC 61000-4-5 Surge Test for Industrial Signal Lines • Max Clamping Voltage of 28.4 V at 40 A of 8/20 µs Surge Current • Standoff Voltage: 22 V • Tiny 4 mm2 Footprint • Survives Over 5,000 Repetitive Strikes of 35 A 8/20 µs Surge Current at 125°C • Robust Surge Protection: – IEC 61000-4-5 (8/20 µs): 40 A – IEC 61643-321 (10/1000 µs): 5 A • Low Leakage Current – 3.