RAIL-MOUNTABLE CURRENT SENSOR

No Preview Available !

±50 A DIN RAIL-MOUNTABLE CURRENT SENSORS
GENERAL DESCRIPTION
The ModuLink ±50A isolated current sensors are easy-
to-use devices, tailored for power electronics applica-
tions. When employed with imperix’s BoomBox control
platform, the sensors provide plug&play connectivity
and can be directly powered by the control platform.
The devices produce a balanced full-differential out-
put signal, proportional to the current voltage. For best
EMC performance, the output signal is typically meant
to be carried by a shielded twisted pair embedded in
RJ45-type cables.
Modulink sensors can be easily clipped on 35mm DIN
rails and are compatible with up to 6 mm2 wires. They
guarantee the galvanic isolation of the sensing circuit
up to 1 kVRMS
KEY FEATURES AND SPECIFICATIONS
–– ± 50 A measuring range
–– 0.2-6mm2 conductor cross-section (AWG 10-24)
–– Minimum 200 kHz measurement bandwidth
–– Balanced full-differential signal output
–– Typical sensitivity of 99.0 mV/A
–– 1.0 kVPK galvanic isolation (permanent)
–– ± 0.45 % typical precision
–– Compatible with standard ± 15 V power supplies
–– Mountable on 35 mm DIN rails
I+
2000:1
LAH 50-P
I-
R
GND
1 VCC
power supplies, 2
lters
3
VCC
GND
VCC
4 VO+
5 VO-
VEE
6 GND
7 VEE
8 VEE
BOOMBOX CONFIGURATION
The recommended configuration for the BoomBox is
shown in Table 1 :
Sensitivity
99.0 mV/A
Filter
Gain
Filter = NONE G= 2
Input
High-impedance
Table 1.  Suggested configuration of the BoomBox
Imperix recommends to consider calibrating each sen-
sor for improved accuracy. When difficult, at least the
offset shall be compensated for.




imperix

DIN-50A Datasheet Preview

DIN-50A Datasheet

RAIL-MOUNTABLE CURRENT SENSOR

No Preview Available !

6
5
4
3
2
MECHANICAL DIMENSIONS
D
-
38,5
-
26,5
C
-
+
94,5
1
D
C
ABSOLUTE MAXIMUM RATINGS
Parameter
B Maximum tolerable input current
Maximum working isolation voltage
Highest allowable short-term isolation voltage (60s)
Power supply voltages
Symbol
Iin,max,abs
VIORM
VIOTM
±VCC
Test conditions
Min.
Typ.
Max.
Unit
-
50
-
A
B
-
-
±12.0
1.0
4.0
±15.0
-
-
±16.0
kVPEAK
kVPEAK
V
SENSOR PARAMETERS
Parameter
A
Input current range – peak
Input current range – rms
Nominal sensitivity
6
5
Uncalibrated sensitivity error 6
Sensitivity error over temperature
Input-referred offset
Input-referred offset over temperature
Measurement bandwidth
Settling time
Input impedance
Input-referred noise
Output voltage range
Output current (short circuit)
Power consumption
Symbol
Iin,nom,peak
Iin,nom,rms
G
GERR
GERR,t
IO
IO,t
f3dB
td
RIN
In
Vo,max
IOUT
PDD
Test conditions
Conçu par
DLY
4
3
TA = 25°C
TA = 25°to 85 °C
TA = 25°C
TA = 25°to 85 °C
10%, -45A to +45A input step
TA = 25°C
On ±15V power supplies, Iin = 0
6  Valid only for sensors sold after January 2017.
Min.
Vérifié par
-
im- perix
-
-
-
-
-
-
-
-
-
-
-
-
Typ.
Max.
Unit
Approuvé par
Date
Date
A
±50
-01.10.2015
A
01.10.2015
±41
99.0
±0.45
- ModuLinAk 50A DIN rail sensor
ML5- 0ADIN
2
mV/A
Modification
1
Feuille
1/1
±2.35 %
±0.4
-
%
±0.05
±0.4
A
±0.2
±0.6
A
200
-
kHz
-
2.0
μs
-
2.1
0.05
-
A
±4.95
± VCC V
±85
-
mA
450
-
mW
CONNECTOR PINOUT
Pin Color
1
orange stripe
2
orange solid
3
green stripe
4
blue solid
Description
+15 V
0V
Signal positive output / current output
Pin Color
5
blue stripe
6
green solid
7
brown stripe
8
brown solid
Description
Signal negative output
0V
-15 V
CONTACT
imperix SA
Rue de l’Industrie 17
1950 Sion, Switzerland
phone: +41 (0)27 552 06 60
fax: +41 (0)27 552 06 69
www.imperix.ch, sales@imperix.ch
ABOUT US
Imperix SA (Ltd.) is a company established in Sion, Swit-
zerland. Its name is derived form the Latin verb imperare,
which stands for controlling and refers to the company’s
core business: the control of power electronic systems.
Imperix SA commercializes hardware and software solu-
tions dedicated to the fast and secure implementation of
pilot systems and plants in the field of power conversion,
energy storage and smart grids.
NOTE
While every effort has been made to ensure the accuracy
of this publication, no responsibility can be accepted for
errors or omissions.
Data may change, as well as legislation, and the reader
is strongly advised to obtain copies of the most recently
issued regulations, standards, and guidelines.
This publication does not form the basis of a contract.
Copyright 2016. All rights reserved.


Part Number DIN-50A
Description RAIL-MOUNTABLE CURRENT SENSOR
Maker imperix
PDF Download

DIN-50A Datasheet PDF






Similar Datasheet

1 DIN-50A RAIL-MOUNTABLE CURRENT SENSOR
imperix





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z



Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy