Part number:
BRKM-P
Manufacturer:
Advanced XTAL Products
File Size:
199.61 KB
Description:
Differential pressure sensing quartz crystal resonator block.
BRKM-P_AdvancedXTALProducts.pdf
Datasheet Details
Part number:
BRKM-P
Manufacturer:
Advanced XTAL Products
File Size:
199.61 KB
Description:
Differential pressure sensing quartz crystal resonator block.
BRKM-P, DIFFERENTIAL PRESSURE SENSING QUARTZ CRYSTAL RESONATOR BLOCK
DIFFERENTIAL PRESSURE SENSING QUARTZ CRYSTAL RESONATOR BLOCK BRKM-P APPLICATIONS BRKM-P is a quartz crystal resonator assembly, which consists of a measuring and a reference quartz crystal, both packaged in a rectangular enclosure.
The resonance frequency varies with pressure-induced stress.
BRKM-P is designed as a component for precision electronic differential pressure transducers, manometers and controllers with a frequency output for conversion of absolute pressure or differential pressure t
BRKM-P Features
* In gauges of differential pressure BRKM-P is used to convert a pressure difference to a differential frequency output signal fout =fMEASURING
* fREFERENCE. An absolute pressure ( or differential pressure) P1 is applied to diaphragm (1), while the absolute atmospheric pressure (basic pressur