Description
UL
File Number: E315805
Industry Standards (in Conjunction with OVP Device) Solutions available for GR-1089-CORE, ITU-T and a combination of both.Absolute Maximum Ratings (@ TA = 25 °C Unless Otherwise Noted)
Symbol Parameter
Part Number
Value
Unit
TBU-PL060-xxx-WH
600
Vimp
Peak impulse voltage withstand with duration less than 10 ms TBU-PL075-xxx-WH
750
V
TBU-PL085-xxx-WH
850
TBU-PL060-xxx-WH
350
Vrms
Continuous A.C.RMS voltage
TBU-PL075-xxx-WH
400
V
TBU-PL085-xxx-WH
Features
- Superior circuit protection.
- Overcurrent & overvoltage protection.
- Blocks surges up to rated limits.
- High-speed performance.
- Small SMT package.
- RoHS compliant.
- Agency recognition:
Additional Information Click these links for more information:.