AKR-C420L - AC Current transducer
AC Current transducer AKR-C420L Transducer for the electronic measurement AC waveforms current, with galvanic isolation between the primary (High power) and the secondary circuits (Electronic circuit).
Jumper selectable ranges and True RMS 4-20mA current output.
IPN = 2..200A Electrical data Primary Nominal CurrentAnalogue Output Signal1) IPN (A.t.RMS) 2,5 10,20,50 100,150,200 Vc RL Vb Vd f IOUT (mA) 4-20 4-20 4-20 AKR 5 C420L AKR 50 C420L AKR 200 C420L 24 Type RoHS Date Code JULY 2006 planned
AKR-C420L Features
* VFD and SCR waveforms current measurement
* True RMS responding
* 4-20 mA Current output
* Loop powered transducers
* Panel mounting
* Accurate
* Jumper selectable ranges Supply voltage (Loop powered) Load resistance see power supply diagra