LGT1502-50 - Fast Transformer
LinkCom Manufacturing Co.,Ltd LGT1502-50 G . Fast Transformer Designed to meet UL 60950-1 and IEC 60950-1 requirements for supplementary insulation RoHS Compliant Operating Temperature -40°C to 85°C Electrical Specifications @25℃ Inductance: Leakage Inductance: Interwinding Capacitance THD PIN 1-4 = 10uH ±10% @ 10KHz/0.1V/Series (PIN 2-3 Short) PIN 1-4 = 0.25uH typ. @ 100KHz/0.1V (PIN 2-3, PIN 5-6-7-8 Short) PIN 1-8 = 20pF Max. @ 100KHz/0.1V (PIN 1-2-3-4, PIN 5-6-7-8 Short) PIN 1-4 to PIN 8.