MAX3050 - Low-Supply Current CAN Transceivers

Datasheet Summary

Description

The MAX3050 and MAX3057 interface between the CAN protocol controller and the physical wires of the bus lines in a control area network (CAN).

They are primarily intended for systems requiring data rates up to 2Mbps and feature ±80V fault protection against shorts in highvoltage power buses.

Features

  • ±80V Fault Protection for 42V Systems.
  • Four Operating Modes:.
  • High-Speed Operation Up to 2Mbps.
  • Slope-Control Mode to Reduce EMI (40kbps to 500kbps).
  • Standby Mode.
  • Low-Current Shutdown Mode.
  • AutoShutdown when Device is Inactive (MAX3050).
  • Automatic Wake-Up from Shutdown (MAX3050).
  • Thermal Shutdown.
  • Current Limiting.
  • Fully Compatible with the ISO 11898 Standard Ordering Information.

📥 Download Datasheet

Datasheet preview – MAX3050

Datasheet Details

Part number MAX3050
Manufacturer Maxim
File Size 548.10 KB
Description Low-Supply Current CAN Transceivers
Datasheet download datasheet MAX3050 Datasheet
Additional preview pages of the MAX3050 datasheet.
Other Datasheets by Maxim

Full PDF Text Transcription

Click to expand full text
MAX3050/MAX3057 ±80V Fault-Protected, 2Mbps, Low-Supply Current CAN Transceivers General Description The MAX3050 and MAX3057 interface between the CAN protocol controller and the physical wires of the bus lines in a control area network (CAN). They are primarily intended for systems requiring data rates up to 2Mbps and feature ±80V fault protection against shorts in highvoltage power buses. They provide differential transmit capability to the bus and differential receive capability to the CAN controller. The MAX3050 and MAX3057 have four modes of operation: high speed, slope control, standby, and shutdown. Highspeed mode allows data rates up to 2Mbps.