Click to expand full text
RPS-500
Features
Analog Ranging Card 2500 Volts Isolation 0 -10 VDC Analog Voltage 4 - 20 mA Analog Current Ranges 2"-14", 5"-36", 5"-72", 10"-240" Inverting Switch Zero, Span, Sample & Hold Controls 120VAC or 24VDC Power Input
www.DataSheet4U.com analog voltage
The RPS-500 ranging board was designed to give and current outputs proportional to distance and can be used with the RPS-100, RPS300, RPS-325 or RPS-326. It is a fast, accurate means of converting analog pulse width generated by the ultrasonic sensor into analog voltage and current. Ranges available are 2" to14", 5" to 36", 5" to 72", 10" to 240" ZERO & SPAN CONTROLS The RPS-500 analog card comes with a zero and span control. These two potentiometers allow the analog signal to be adjusted over a desired range.