LHR, LGR 4/5000 Series
10...30 Watt AC-DC Converters
Input voltage ranges 85...265 V AC 88…168 V DC 1 or 2 outputs up to 48 V DC 4300 V DC I/O electric strength test voltage
LGA
• Class II equipment (double insulation) • Short circuit protection • Compact, low cost solution
Selection chart
Output 1 Uo nom Io nom [V DC] [A] 3.3 3 3.3 7 5 2 5 5 12 1.2 12 2.5 15 1 15 2 24 0.6 24 1.25 3.3 1.5 3.3 2.5 +5 1.25 +5 2.5 +5 1 +5 2.5 +12 0.6 +12 1.25 +15 0.5 +15 1.0 +24 0.3 +24 0.625 Output 2 Uo nom Io nom [V DC] [A] +5 1 +5 2.5 -5 1.25 -5 2.5 +12 0.5 +12 1.25 -12 0.6 -12 1.25 -15 0.5 -15 1.0 -24 0.3 -24 0.625 Input voltage Ui Rated power TA = 50 °C Po tot [W] 10 23 10 25 14.4 30 15 30 14.4 30 10 20.8 12.5 25 11 27.5 14.