LL4001G
FEATURES
- Plastic package has carries underwriters
- Ideal for automated placement
- Surge overload rating to 30 Ampers peak
- Reliable low cost construction utilizing molded plastic technique results in in-expensive product
- pliant to Ro HS Directive 2011/65/EU and in accordance to WEEE 2002/96/EC
- Halogen-free according to IEC 61249-2-21 definition
MELF
MECHANICAL DATA
Case: MELF Molding pound, UL flammability classification rating 94V-0 Packing code with suffix "G" means green pound (halogen-free) Mounting position: Any Polarity: Indicated by silver cathode band Weight: 0.12 g (approximately)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS (TA=25°C unless otherwise noted)
PARAMETER
LL40 LL40 LL40 LL40 LL40 SYMBOL
01G 02G 03G 04G 05G
Maximum repetitive peak reverse voltage
VRRM
50 100 200 400 600
Maximum RMS voltage Maximum DC blocking voltage
VRMS VDC
35 70 140 280 420 50 100 200 400 600
Maximum average forward rectified current
IF(AV)
Peak forward surge current,...