TPE-502
Description
Value Notes
Actuation force
Force range
Long term dri
Force to reach 10MΩ linear region of log/log 1kg for 48hrs
< 30g / < 10g Average of 100 samples
Up to 5kg
Higher forces can be achieved with custom sensor and actuation methods
< 2% Per log time
Single part repeatability 100 actuations of 1kg
2% 1 standard deviation/mean
Part to part repeatability 100 sensors same batch
+/- 4% 1 standard deviation/mean
Low temp. storage
- 20°C for 250hrs
8% Avg. change in resistance of 5 sensors
High temp. storage
+85°C for 250hrs
4% Avg. change in resistance of 5 sensors
High humidity storage
+85°C/85%RH for 250hrs
8% Avg. change in resistance of 5 sensors
Lifecycle durability (10M) 1kg force at 3Hz
7% Avg. change in resistance of 4 sensors
Hysteresis
100 actuations of 1kg
5% Avg. change in resistance of 100 samples
Operational temp. range 100 cycles at 0.5kg
- 20 to +85°C
Device characteristics and mechanical data stated in orange text refer to...