FARM1C12 - FARM Filter/ Autoranging Rectifier Module
Power-Up Sequence.
(see Fig.
8): 1.1 Upon application of input power, the output bus capacitors begin to charge.
The thermistor limits the charge current, and the exponential time constant is determined by the hold-up capacitor value and the thermistor cold resistance.
The slope (dv/dt) of the capac
FARM1C12 Features
* EMI filtering Choice of 500W or 750W modules 96% Efficiency Autoranging 115/230Vac input Microprocessor controlled Inrush current limiting Mini sized package Power fail signal Module enable Data Sheet FARM T