DESCRIPTION
The KSDU is factory fixed from 0.1 s to 10,230 s and does not include the DIP switch. These series are excellent choices for process control systems and OEM equipment. Operation Upon application of input voltage, the time delay begins. The output is de-energized before and during the time delay. At the end of the time delay, the output energizes and remains energized until input voltage is removed. Reset: Removing input voltage resets the time delay and output. Function Delay On Make 2 Universal Voltage Ranges From 24 ... 240 V AC/DC Digital Integrated Circuitry Switch Selectable Delays From 0.1 s ... 2.8 h in 3 Ranges or Factory Fixed +/-0.5% Repeat Accuracy 1 A Steady - 10 A Inrush Totally Solid State and Encapsulated Approvals: V = Voltage R = Reset TD = Time Delay L = Load = Undefined time Connection Accessories Female quick connect P/N: P1015-64 (AWG 14/16) Quick connect to screw adaptor P/N: P1015-18 Dashed lines are internal connections. Load may be connected to terminal 3 or 1.