S-19161A
Features
- High-accuracy voltage detection circuit
Overcharge detection voltage
3.500 V to 4.800 V (5 m V step)
Accuracy ±15 m V
Overcharge release voltage
3.100 V to 4.800 V- 1
Accuracy ±50 m V
Overdischarge detection voltage
2.000 V to 3.000 V (10 m V step) Accuracy ±50 m V
Overdischarge release voltage
2.000 V to 3.400 V- 2
Accuracy ±75 m V
Discharge overcurrent 1 detection voltage 5 m V to 100 m V (0.5 m V step)
Accuracy ±1.5 m V
Discharge overcurrent 2 detection voltage 10 m V to 100 m V (1 m V step)
Accuracy ±3 m V
Load short-circuiting detection voltage
20 m V to 100 m V (1 m V step)
Accuracy ±5 m V
101 m V to 300 m V (1 m V step)
Accuracy ±10 m V
Charge overcurrent detection voltage
-100 m V to -5 m V (0.5 m V step) Accuracy ±1.5 m V
- Detection delay times are generated only by an internal circuit (external capacitors are unnecessary).
- Discharge overcurrent control function
Release condition of discharge overcurrent status: Load disconnection
Release voltage of discharge...