ABLIC S-82C5A
BATTERY PROTECTION
FEATURES
● High-accuracy voltage detection for each cell Overcharge detection voltage n Overcharge release voltage n 3.900 V to 4.500 V (25 mV step) Accuracy ±20 mV 3.500 V to 4.500 V*1 Accuracy ±50 mV Overdischarge detection voltage n Overdischarge release voltage n 2.000 V to 3.200 V (100 mV step) Accuracy ±50 mV 2.000 V to 3.400 V*2 Accuracy ±100 mV● Three-level discharge overcurrent detection Discharge overcurrent 1 detection voltage Discharge overcurrent 2 detection voltage 10 mV to 200 mV (5 mV step) 20 mV to 300 mV (5 mV step) Accuracy ±5 mV Accuracy ±10 mV Load short-circuiting detection voltage 50 mV to 400 mV (10 mV step) Accuracy ±20 mV
● Charge overcurrent detection Charge overcurrent detection voltage −200 mV to −10 mV (5 mV step) Accuracy ±5 mV
● Discharge overcurrent 1 detection delay time is settable by an external capacitor (The other delay time are internally fixed)
● Power saving control by a control pin
● 0 V battery charge: Enabled, inhibited
● Power-down function...