AMPIRE AG-640480C2FTCW00
LCD
ABSOLUTE MAXIMUM RATINGS
NORMAL TEMP. ITEM Ambient Temperature Humidity (without Condensation) Note 2 0 Note 2,4 OPERATING MIN MAX 50 STORAGE MIN -20 Note 3,4 MAX 70 Note 3 Note 4 Ta≤50°C:80%RH max Ta›50°C: Absolute humidity must be lower than the humidity of 80%RH at 50°C Ta at -20°C will be < 48hrs at 70°C will be < 120hrs Background color changes slightly depending on ambient temperature. This phenomenon is reversible. Date :2008/6/27 AMPIRE CO., LTD. 2 3. ELECTRICAL SPECIFICATION (Condition : Ta=25°C) Item Supply Voltage Symbol VDD-Vss Conditions 0℃ Specifications min typ max 3.0 4.75 22.9 21.9 21.0 0.8 VDD Vss 3.3 5.0 23.3 22.3 21.4 VDD 0.2VDD 3.0 15 3.6 5.25 23.7 22.7 21.8 - Unit V LCD Driving Voltage VEE-Vss VDD=5V 25℃ 50℃ V VIH Input Voltage VIL Power Supply Current for LCM (Typical case) IDD IEE H level L level VDD=5.0V VEE-VSS=22.3V FLM=70Hz V 6.0 mA 30 . 4. CCFL B/L ELECTRICAL SPECIFICATION (Condition : Ta=25°C) Item Lamp Voltage Lamp Current Lamp Power consumption Starting...