Click to expand full text
ADVANCED PRESSURE TECHNOLOGY
Series AP 30, 35 & 36
1/4 INCH DIAPHRAGM VALVE
Springless – manual and pneumatic (NC & NO)
Engineering Data — Series AP 30, 35 & 36 1/4 inch valve array
• Replaceable seat • Stainless steel 316L VAR
secondary remelt or Ni-Cr-Mo alloy construction
• Operating pressures
from 125 psig (9 bar) to 3,000 psig (207 bar)
• LOTO and indicating
switch options
• Flow capacity
0.23 to 0.29 Cv
• Surface finish
15 Ra max /10 Ra avg
(10, 7 & 5 Ra max options)
• FA option 1.125 inch C-seal • Constant bleed option
5, 8 and 15 slpm of N2 @ 80 psig (5.5 bar) refer to PN 430
• Multi-port options
available (refer to page 4)
• Two step pneumatic valve
option: dual operation – metered or full open
• Installation and operating
instructions available at www.aptech-online.