FEATURES
❑ 48 channels provided by three 16-channel multiplexers ❑ Radiation performance - Total dose: - SEU: 150 krads(Si), Dose rate = 50 - 300 rads(Si)/s Immune up to 90 MeV-cm2/mg - SEL: Immune by process design ❑ Full military temperature range ❑ Low power consumption < 45mW ❑ One address bus (A0-3) and three enable lines afford flexible organization ❑ All channel inputs protected by ±20V nominal transorbs ❑ Fast access time < 500ns typical ❑ Break-Before-Make switching ❑ High analog input impedance (power on or off) ❑ Designed for aerospace and high reliability space applications ❑ Packaging – Hermetic ceramic - 96 leads, 1.32"Sq x 0.20"Ht quad flat pack - Typical Weight 15 grams ❑ DSCC SMD 5962-09203 pending Note: Aeroflex Plainview does not currently have a DSCC certified Radiation Hardened Assurance Program. GENERAL DESCRIPTION
Aeroflex’s It is guaranteed operational from -55°C to +125°C. The ACT8513 is ideal for demanding military and space applications. ORGANIZATION AND APPLICATION The ACT8513 consists of three 16 channel multiplexers arranged as shown in the Block Diagram.