Datasheet4U Logo Datasheet4U.com

A5354CA - SMOKE DETECTOR

General Description

The A5354CA is a low-current CMOS circuit providing all of the required

Key Features

  • for an ionization-type smoke detector. A networking capability allows as many as 125 units to be interconnected so that if any unit senses smoke, all units will sound an alarm. In addition, special features are incorporated to facilitate alignment and test of the finished smoke detector. This device is designed to comply with Underwriters Laboratories Specification UL217. The internal oscillator and timing circuitry keeps standby power to a minimum by powering down the device for 1.66 seconds an.

📥 Download Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
Data Sheet 26110.6 5354 NO CONNECT. 1 NC I/O 2 LOW-V SET 3 NO CONNECT. 4 NC LED 5 LOGIC OSC. & TIMING 16 GUARD 2 15 DETECT. IN 14 GUARD1 13 SENSITIVITY SET 12 OSC. CAP. + SUPPLY 6 V DD TIMING RES. 7 HORN DRIVER FEEDBACK 8 11 HORN 2 10 HORN 1 V SS 9 – SUPPLY Dwg PC-004-1 SMOKE DETECTOR WITH INTERCONNECT The A5354CA is a low-current, CMOS circuit providing all of the required features for an ionization-type smoke detector. A networking capability allows as many as 125 units to be interconnected so that if any unit senses smoke, all units will sound an alarm. In addition, special features are incorporated to facilitate alignment and test of the finished smoke detector. This device is designed to comply with Underwriters Laboratories Specification UL217.