ABSOLUTE MAXIMUM RATINGS
Load Supply Voltage, VBB . . . . . . . . . . 50 V Output Current, IOUT (Continuous) . . . . . . . . . . . . . . ±1.5 A* Logic Supply Voltage, VCC . . . . . . . . . 7.0 V Logic/Reference Input Voltage Range, VIN . . . . . . . . . . . -0.3 V to VCC + 0.3 V Sense Voltage, VS . . . . . . . . . . . . . . . . 1.0 V Package Power Dissipation, PD . . . . . . . . . . . . . . . . . . . . See Graph Operating Temperature Range, TA . . . . . . . . . . . . . . . . . -20˚C to +85˚C Junction Temperature, TJ . . . . . . . +150˚C† Storage Temperature Range, TS . . . . . . . . . . . . . . . . -55˚C to +150˚C * Output current rating may be limited by duty cycle, ambient temperature, and heat sinking. Under any set of conditions, do not exceed the specified current rating or a junction temperature of 150˚C. † Fault conditions that produce excessive junction temperature will activate the device’s thermal shutdown circuitry. These conditions can be tolerated but should be avoided. The outputs are rated for continuous output currents to ±1.5 A and operating voltages to 50 V.