The following content is an automatically extracted verbatim text
from the original manufacturer datasheet and is provided for reference purposes only.
View original datasheet text
Data Sheet
FEATURES
Initial accuracy A grade: ±0.70% (maximum) B grade: ±0.35% (maximum)
Maximum temperature coefficient A grade: 50 ppm/°C B grade: 25 ppm/°C
CLOAD = 0.1 μF to 1 μF Output current: +4 mA/−2 mA Low operating current: 80 μA (typical) Output noise: 6 μV p-p at 1.0 V output Input range: 2.0 V to 18 V Temperature range: −40°C to +125°C Tiny, Pb-free TSOT package
APPLICATIONS
Battery-powered instrumentation Portable medical equipment Communication infrastructure equipment
GENERAL DESCRIPTION
The ADR130 is the first family of tiny, micropower, low voltage, high precision voltage references in the industry. Featuring 0.35% initial accuracy and 25 ppm/°C of temperature drift in the tiny TSOT-23 package, the ADR130 voltage reference only requires 80 μA for typical operation.