Datasheet4U Logo Datasheet4U.com

ADR510 - 1.0V Precision Low Noise Shunt Voltage Reference

Description

PIN CONFIGURATION 3-Lead SOT-23 V+ 1 ADR510 3 TRIM/NC V 2 ADR510 Model Output Voltage (VO) Initial Accuracy (mV) (%) 3.5 0.35 Temperature Coefficient (ppm/؇C) 70 ADR510ART-REEL7 1.000 Designed for space critical applications, the ADR510 is a low voltage (1.000 V), precision shunt-m

Features

  • Precision 1.000 V Voltage Reference Ultracompact 3 mm ؋ 3 mm SOT-23 Package No External Capacitor Required Low Output Noise: 4 ␮V p-p (0.1 Hz to 10 Hz) Initial Accuracy: ؎0.35% Max Temperature Coefficient: 70 ppm/؇C Max Operating Current Range: 100 ␮A to 10 mA Output Impedance: 0.3 ⍀ Max Temperature Range:.
  • 40؇ C to +85؇ C.

📥 Download Datasheet

Datasheet preview – ADR510

Datasheet Details

Part number ADR510
Manufacturer Analog Devices
File Size 344.36 KB
Description 1.0V Precision Low Noise Shunt Voltage Reference
Datasheet download datasheet ADR510 Datasheet
Additional preview pages of the ADR510 datasheet.
Other Datasheets by Analog Devices

Full PDF Text Transcription

Click to expand full text
1.0 V Precision Low Noise Shunt Voltage Reference ADR510 FEATURES Precision 1.000 V Voltage Reference Ultracompact 3 mm ؋ 3 mm SOT-23 Package No External Capacitor Required Low Output Noise: 4 ␮V p-p (0.1 Hz to 10 Hz) Initial Accuracy: ؎0.35% Max Temperature Coefficient: 70 ppm/؇C Max Operating Current Range: 100 ␮A to 10 mA Output Impedance: 0.3 ⍀ Max Temperature Range: –40؇ C to +85؇ C APPLICATIONS Precision Data Acquisition Systems Battery-Powered Equipment: Cellular Phone, Notebook Computer, PDA, and GPS 3 V/5 V, 8-/12-Bit Data Converters Portable Medical Instruments Industrial Process Control Systems Precision Instruments GENERAL DESCRIPTION PIN CONFIGURATION 3-Lead SOT-23 V+ 1 ADR510 3 TRIM/NC V– 2 ADR510 Model Output Voltage (VO) Initial Accuracy (mV) (%) 3.5 0.