Datasheet4U Logo Datasheet4U.com

ADR510 - 1.0V Precision Low Noise Shunt Voltage Reference

General Description

PIN CONFIGURATION 3-Lead SOT-23 V+ 1 ADR510 3 TRIM/NC V 2 ADR510 Model Output Voltage (VO) Initial Accuracy (mV) (%) 3.5 0.35 Temperature Coefficient (ppm/؇C) 70 ADR510ART-REEL7 1.000 Designed for space critical applications, the ADR510 is a low voltage (1.000 V), precision shunt-m

Key Features

  • Precision 1.000 V Voltage Reference Ultracompact 3 mm ؋ 3 mm SOT-23 Package No External Capacitor Required Low Output Noise: 4 ␮V p-p (0.1 Hz to 10 Hz) Initial Accuracy: ؎0.35% Max Temperature Coefficient: 70 ppm/؇C Max Operating Current Range: 100 ␮A to 10 mA Output Impedance: 0.3 ⍀ Max Temperature Range:.
  • 40؇ C to +85؇ C.

📥 Download Datasheet

Datasheet Details

Part number ADR510
Manufacturer Analog Devices
File Size 344.36 KB
Description 1.0V Precision Low Noise Shunt Voltage Reference
Datasheet download datasheet ADR510 Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
1.0 V Precision Low Noise Shunt Voltage Reference ADR510 FEATURES Precision 1.000 V Voltage Reference Ultracompact 3 mm ؋ 3 mm SOT-23 Package No External Capacitor Required Low Output Noise: 4 ␮V p-p (0.1 Hz to 10 Hz) Initial Accuracy: ؎0.35% Max Temperature Coefficient: 70 ppm/؇C Max Operating Current Range: 100 ␮A to 10 mA Output Impedance: 0.3 ⍀ Max Temperature Range: –40؇ C to +85؇ C APPLICATIONS Precision Data Acquisition Systems Battery-Powered Equipment: Cellular Phone, Notebook Computer, PDA, and GPS 3 V/5 V, 8-/12-Bit Data Converters Portable Medical Instruments Industrial Process Control Systems Precision Instruments GENERAL DESCRIPTION PIN CONFIGURATION 3-Lead SOT-23 V+ 1 ADR510 3 TRIM/NC V– 2 ADR510 Model Output Voltage (VO) Initial Accuracy (mV) (%) 3.5 0.