APPLICATIONS
Configurations MAX16491 GENERAL DESCRIPTION
The programmable features include: internal/external reference voltage, output voltage set-point, switching frequency, overcurrentprotection level (OCP), and soft-start timing. Discontinuous current mode (DCM) operation can be enabled using pin-strapping to improve light-load efficiency. The MAX16491 includes multiple protection and measurement features. Positive and negative cycle-by-cycle OCP, short-circuit protection and overtemperature protection (OTP) ensure robust design. Input undervoltage and overvoltage lockout shut down the regulator to prevent damages when the input voltage is out of specification. Regulation is halted in case of an output overvoltage (OVP) event. A status pin indicates that the output voltage is within range and the outputvoltage is in regulation. The device has an analog output that can be configured to report output current or junction temperature. The device is available in a 19-bump (2.2mm x 2.8mm) WLCSP package that provides low thermal resistance and minimizes the printed circuit board area.