Datasheet4U.com

BXA30 Datasheet PDF

Artesyn Technologies BXA30

The BXA15 and BXA30 series is intended to be supplied only from a SELV (Safe Extra Low Voltage) circuit or a TNV (Telecommunications Network Voltage) power source which are insulated from the AC mains by reinforced insulation. The test set-up is per VDE 0877 Part 1 fig.4 with the load < 10 cm's away from the test converter.
Part No. BXA30
Datasheet BXA30 Download
Manufacturer
Artesyn Technologies
Description Design Note 100 Rev
Buy Stock & Price
BXA30 datasheet page 1 preview

FEATURES

● System Protection

FEATURES

● Thermal Considerations
● Input Impedance Considerations 1. Safety and the Low Voltage Directive Basic isolation, tested to 1,500VDC, for EN60950 and UL1950, is provided. SELV TNV DC Distributed Power of 12V, 24V or 48V Central Office -48V Conducted Interference - Level B External Filter: The addition of an external capacitor enables the BXA15 and BXA30 products to meet VDE0871/8-B, EN55022-B and CISPR22-B conducted noise limits. Input Voltage 48 Volt 24 Volt 12 Volt Recommended External Cap. Nippon Chemi-Con SXE series120uF, 100V ITW PAKTRON Capstick series part number 405K100CS4, 4uF @ 100V ITW PAKTRON 405K100CS4 2 * ITW PAKTRON 405K100CS4 capacitors in close parallel. 2. Electromagnetic Compatibility Immunity Good design practice dictates that the electronic system be immune to noise interference. This practice has now been encapsulated in European law in the form of the EMC directive. It is imperative that any system on sale in the European Union meets the terms of the EMC directive and thus carries the CE mark.
BXA30 page 2 preview BXA30 page 3 preview