Astec Semiconductor ATX125-3416
110w Platform With PFC
FEATURES
●●
●
●
●
●
●
●
●
●
●
● Power Factor Correction (PFC) Harmonic current Compliant CE Mark 3.3V output +5VSB Standby supply (SELV) Remote On/Off (ROO) Energy Star High efficiency High MTBF Built-in EMI filter (CISPR 22 Class B) IEC801-2,-4,-5 Power good signal
ELECTRICAL SPECIFICATIONS
INPUT Input range . Frequency . . Input current Efficiency . . . EMI/RFI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90-135 / 180-265 VAC Switch select 47-63 Hz 3 A @ 115 VAC; 1.5A @ 230 VAC >65% @ full load, nominal line FCC Part 15, Subpart B Class B and CISPR 22 OUTPUT Maximum power . . . . . . . Hold-up time . . . . . . . . . . Transient response . . . . . 110 W 17 ms at full load @ 115 / 230 VAC All outputs shall stay within regulation for 20% load change from 10 Hz - 1 KHz and 50% duty cycle condition +3.3 V - trip point <4.5 V +5 V - trip point <7.0 V +12 V - trip point <15.6 V Recycle AC or PS-On to reset Latch off on main outputs if one of the mains short circuit to common (R<0.03 Ohm), but +5 VSB shall remain normal.