FEATURES
4.8 0.5 11.5 *Input Voltage: 90~265VAC *Input Frequency: 47~63Hz *Inrush Current: Does not exceed 30A at 115VAC input or 60A AC input, at cold start 25oC *Safety: UL 1950 / CSA 22.2 No.234 / VDE EN60950 *Load Range: When all outputs are at 60% rated load *EMI: FCC class B / EN55022B condition, the +5V output is set between 4.90~5.10V and all *EMS: Level 3 of IEC-801, 802, 803, 804 other outputs are within the specified voltage accuracy range *Ripple And Noise: Peak to peak ripple and noise for each output is < 1% of each output voltage at rated load Output PIN 115~230VAC +5V Red *Line Regulation: < +/-1% at rated load with +/-10% change +12V Yellow in input voltage -12V Brown *Load Regulation: The output voltage load regulation is less -5V Blue than the values on the table when each output loading changes Black GND +/-40% from 60% rated load while all other outputs at 60% White P.G. rated load *Hold Up Time: 14ms typ. from the last AC line charging pulse to the point when +5V drops down to +4.75V Output Min.