• Part: 2045-47
  • Description: Medium Duty 2-Electrode Gas Discharge Tube
  • Manufacturer: Bourns
  • Size: 147.26 KB
Download 2045-47 Datasheet PDF
Bourns
2045-47
Features - Size: 8 mm diameter, 6 mm length - Low capacitance - High insulation resistance - Ro HS pliant- - UL Recognized Additional Information Click these links for more information: PRODUCT TECHNICAL INVENTORY SAMPLES CONTACT SELECTOR LIBRARY 2045 Series Medium Duty 2-Electrode Gas Discharge Tube Characteristics Test Methods per ITU-T (CCITT) K.12 and IEEE C62.31. Characteristic DC Sparkover ±30 % @ 100 V/s Impulse Sparkover (1) 100 V/μs 1000 V/μs 2045-07 75 V < 500 V < 600 V 2045-09 90 V < 500 V < 600 V Model No. 2045-12 2045-13 120 V 130 V < 500 V < 700 V < 500 V < 700 V 2045-14 145 V < 500 V < 700 V Characteristic 2045-25 2045-30 DC Sparkover ±30 % @ 100 V/s 250 V 300 V Impulse Sparkover (1) 100 V/μs 1000 V/μs < 500 V < 700 V < 700 V < 900 V (1) Impulse Sparkover voltage is defined as typical values of distribution. Model No. 2045-35 350 V < 700 V < 900 V 2045-40 400 V < 800 V < 1000 V 2045-47 470...