BeRex BCG13D
Cascadeable InGaP HBT Gain Block
FEATURES
● 33 dBm Output IP3 at 5dBm/tone● 24.9 dB Gain at 900 MHz
● 18 dBm P1dB
● Highly Reliable InGaP/GaAs HBT Technology
● 50 ohm Cascadeable
● Application: commercial wireless system BCG13D Target Device Performance (Ta = 25°C) Symbols Test Conditions Min Typ Max Frequency Range 5 4000 900 MHz 23.9 24.9 25.9 Gain 1900 MHz 22.0 23.0 24.0 2450 MHz 20.6 21.6 22.6 900 MHz -11.7 S11 1900 MHz -10.4 2450 MHz -11.9 900 MHz -7.6 S22 1900 MHz -13.4 2450 MHz -12.0 900 MHz 31.0 33.0 OIP3 1900 MHz 30.7 32.7 2450 MHz 29.5 31.5 900 MHz 17.3 18.3 P1dB 1900 MHz 17.2 18.2 2450 MHz 16.4 17.4 Ic Vc = 5.0V 59 69 79 Vc 5.0 dG/dT -0.007 Rth Thermal Resistance 85 Test conditions unless otherwise noted. 1. Device performance is measured on BeRex evaluation board at 25C, 50 ohm system 2. OIP3 measured with two tones at an output power of 5 dBm/tone separated by 1 MHz. Unit MHz dB dB dB dBm dBm mA V dB/°C °C/W
ABSOLUTE MAXIMUM RATINGS
Parameter Rating Operating Case temperature -40 to +85°C Storage Tempera...