*RoHS COMPLIANT
Features
■ Compliant with IEEE 802.3 standards
■ Designed for 10/100/1000 Base-T full duplex
■ Supports four pairs of Category 5 UTP cables
■ Extended operating temperature range
■ RoHS compliant*
Applications
■ Ethernet
PT61022XEL 10/100/1000 Base-T Transformer
Electrical Specifications @ 25 °C
Turns Ratio (±5 %) .................1CT*:1CT* Inductance.......350 µH min. @ 100 KHz,
0.1 Vrms, 8 mA DC Bias Leakage Inductance............ 0.5 µH max.
@ 100 KHz, 0.1 Vrms Cww......................................... 25 pF typ.
@ 100 KHz, 0.1 Vrms DCR....................................... 0.9 Ω max. Insertion Loss
0.3-100 MHz ....................-1.1 dB max. Return Loss
0.3-30 MHz ......................-18 dB min. 30-60 MHz .......................-14 dB min. 60-80 MHz ..........