Datasheet4U.com

DG502UA Datasheet PDF

CDVI DG502UA

This device comes with a varistor. The varistor must be connected to the strike terminal (electromagnet…) operated by the device.
Part No. DG502UA
Datasheet DG502UA Download
Manufacturer CDVI
Description 2-DOOR CONTROLLER
Buy Stock & Price
DG502UA datasheet page 1 preview

DESCRIPTION

Request-to-Exit input 1 Request-to-Exit input 2 Common REX inputs N/C Contact door Common N/O Contact door Varistor Jumper for reset Tamper Switch output NOTICE DE This device comes with a varistor. If this product works with many strikes, each of them should have a varistor. The varistor controls the overload produced by the strike coil – self-effect. If you are using a « Shear Lock » electromagnetic lock, it is recommended to use a separate power supply than the one connected to the DG502U! Edition 12/2005 Technical specifications Input voltage Outputs Tamper switch Cardholders Master code Inputs Controller Distance between the remote readers and the controller 12 VAC/DC 2 form C relays N/O and N/C 3A @ 125V 500 MA @ 50 VAC/DC 500 badges 5-digit master code 2 REX inputs 12-digit keypad with built-in buzzer (Audible feedback) 60 cm minimum, 50 meters maximum (cable spec. 7 x 0.6 mm2) Default Factory Values Master Code: Door release time: Key-in Keypad: Enrollment unit: 123...