AMT132S
AMT132S is MODULAR INCREMENTAL ENCODER manufactured by CUI.
- Part of the AMT13 comparator family.
- Part of the AMT13 comparator family.
DESCRIPTION
: MODULAR INCREMENTAL ENCODER
FEATURES
- patented capacitive ASIC technology
- low power consumption
- incremental resolutions up to 4096 PPR
- resolutions programmable with AMT Viewpoint™ PC software
- differential line driver versions
- digitally set zero position
- pact modular package with locking hub for ease of installation
- radial and axial cable connections
- -40~125°C operating temperature date 06/21/2019 page 1 of 8
ELECTRICAL parameter power supply start up time current consumption single ended channels differential channels conditions/description
VDD with unloaded output output high level output low level output current (per channel) rise/fall time output high level output low level output current (per channel) rise/fall time min 4.5
VDD-0.1
3 7 typ 5
200 16
11 max 5.5
0.1 15
0.1 25 20 units
V ms m A
V V m A ns
V V m A ns
INCREMENTAL CHARACTERISTICS parameter conditions/description min typ max units channels
CMOS Voltage (S) Quadrature Line Driver (Q)
A, B, Z A, ¯A, B, B¯, Z, Z¯ waveform
CMOS voltage square wave phase difference
A leads B for CCW rotation (viewed from front) quadrature resolutions1
48, 96, 100, 125, 192, 200, 250, 256, 360, 384, 400, 500, 512, 768, 800, 1000, 1024, 1600, 2000, 2048, 2500, 4096
PPR index2 one pulse per 360 degree rotation accuracy
0.2 degrees quadrature duty cycle
50 %
Notes:
1. Resolutions programmed with AMT Viewpoint™ PC software. Default resolution set to 2048 PPR. Listed as pre-quadrature, meaning final number of counts is PPR x 4. 2. Zero position alignment set with AMT One Touch Zero™ module, AMT Viewpoint™ PC software, or serial mands cui.
For more information, please visit the product page. CUI Inc │ SERIES: AMT13 │ DESCRIPTION
: MODULAR INCREMENTAL ENCODER date 06/21/2019 │ page 2 of 8
MECHANICAL parameter motor shaft length weight axial play hub set screw to shaft torque rotational speed (at each resolution)
ENVIRONMENTAL parameter operating temperature...