CTDD1106S-S
CTDD1106S-S is DC/DC Converters manufactured by Central Technologies.
DC/DC Converters
.. ctparts.
SPECIFICATIONS
CTDD1106S-S Series
Fixed Input Isolated & Unregulated 1W Output, Single Output
Part Number CTDD1106S-0505S-1 CTDD1106S-0509S-1 CTDD1106S-0512S-1 CTDD1106S-0515S-1 CTDD1106S-1205S-1 CTDD1106S-1209S-1 CTDD1106S-1212S-1 CTDD1106S-1215S-1 CTDD1106S-2405S-1 CTDD1106S-2409S-1 CTDD1106S-2412S-1 CTDD1106S-2415S-1
Vin Nom. 5VDC 5VDC 5VDC 5VDC 12VDC 12VDC 12VDC 12VDC 24VDC 24VDC 24VDC 24VDC
Input Range 4.5-5.5VDC 4.5-5.5VDC 4.5-5.5VDC 4.5-5.5VDC 10.8-13.2VDC 10.8-13.2VDC 10.8-13.2VDC 10.8-13.2VDC 21.6-26.4VDC 21.6-26.4VDC 21.6-26.4VDC 21.6-26.4VDC
Vout 5VDC 9VDC 12VDC 15VDC 5VDC 9VDC 12VDC 15VDC 5VDC 9VDC 12VDC 15VDC
Iout Max. (m A) 200 111 83 67 200 111 83 67 200 111 83 67
Iout Min. (m A) 20 12 9 7 20 12 9 7 20 12 9 7
Effi(Typ.) 78% 79% 80% 78% 78% 80% 81% 79% 79% 80% 81% 79%
Not shown at actual size.
ISOLATION SPECIFICATIONS
Item Isolation Voltage Isolation Resistance Test Condition Tested for 1 minute Test at 500VDC MIN 1000 1000 TYP MAX Units VDC MΩ
Features
Efficiency: To 80% Temperature Range: -40°C to 85°C Isolation: 1KVDC Package: UL94-V0 Miscellaneous: Single Output Voltage. No heatsink required. No external ponents required. Industry standard pinout. Small footprint. Custom service available. Samples available.
Item Output Power Line regulation Load regulation Output voltage accuracy Temperature drift Output ripple Switching frequency
OUTPUT SPECIFICATIONS
Test Condition For Vin change of 1% 10% to 100% full load See tolerance envelope graph 100% full load 20MHz Bandwidth Full load, nominal input 100 50 150 0.03 75 200 %/°C m Vp-p KHz MIN 0.1 TYP MAX 1 1.2 15 Units W % %
Note: 1. All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
TYPICAL CHARACTERISTICS CHARACTERISTICS
Short Circuit Protection: 1 second Temperature Rise at Full Load: 25°C Max. 15°C Typ. Cooling: Free air convection Operating Temperature Range:...