Datasheet4U Logo Datasheet4U.com

CA-IS2092VW - Isolated RS-485/RS-422 Transceivers

Download the CA-IS2092VW datasheet PDF. This datasheet also covers the CA-IS2092W variant, as both devices belong to the same isolated rs-485/rs-422 transceivers family and are provided as variant models within a single manufacturer datasheet.

General Description

The CA-IS2092x family of devices is galvanically-isolated RS-485/RS-422 transceivers with built-in isolated DC-DC converter, that eliminates the need for a separate isolated power supply in space constrained isolated designs.

Key Features

  • High-Performance and Compliant with RS-485 EIA/TIA-485 Standard.
  • 0.5Mbps data rate.
  • 1/8 unit load enables up to 256 nodes on the bus.
  • 3V to 5.5V supply voltage range, and the CAIS2092VW provides individual logic supply input.
  • Integrated DC-DC Converter for Cable-side Power.
  • 3.3V and 5V output options (VISO ≤ VCC).
  • High integration with internal transformer.
  • Soft-start reduces input inrush current.
  • Overload and short-circuit protection.
  • T.

📥 Download Datasheet

Note: The manufacturer provides a single datasheet file (CA-IS2092W-Chipanalog.pdf) that lists specifications for multiple related part numbers.

Datasheet Details

Part number CA-IS2092VW
Manufacturer Chipanalog
File Size 1.53 MB
Description Isolated RS-485/RS-422 Transceivers
Datasheet download datasheet CA-IS2092VW Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
Shanghai Chipanalog Microelectronics Co., Ltd. CA-IS2092W, CA-IS2092VW Version 1.05 CA-IS2092 Isolated RS-485/RS-422 Transceivers with Integrated DC-DC Converter 1. Features • High-Performance and Compliant with RS-485 EIA/TIA-485 Standard ▪ 0.5Mbps data rate ▪ 1/8 unit load enables up to 256 nodes on the bus ▪ 3V to 5.5V supply voltage range, and the CAIS2092VW provides individual logic supply input • Integrated DC-DC Converter for Cable-side Power ▪ 3.3V and 5V output options (VISO ≤ VCC) ▪ High integration with internal transformer ▪ Soft-start reduces input inrush current ▪ Overload and short-circuit protection ▪ Thermal shutdown • Integrated Protection for Robust Communication ▪ 3.