CHT-RUBY Overview
Description
The CHT-RUBY is a general-purpose triple operational amplifier combined with a bandgap voltage reference for applications with an operating temperature range of -55 to 225°C. The three operational amplifiers can be configured in an instrumentation amplifier with external resistors, while the built-in voltage reference provides complete bridge excitation for sensor applications.
Key Features
- Operating temperature: Junction temperature from -55°C to 225°C (other temperature range: contact marketing)
- Single or symmetrical supply operation (Operational Amplifier)
- Validated at 225°C for 1000 hours (and still on-going)
- Package: CSOIC16 Voltage Reference
- Fixed Reference Voltage: 5V