CHT-RUBY Overview
The CHT-RUBY is a general-purpose triple operational amplifier bined with a bandgap voltage reference for applications with an operating temperature range of -55 to 225°C. The three operational amplifiers can be configured in an instrumentation amplifier with external resistors, while the built-in voltage reference provides plete bridge excitation for sensor applications. The total precision (absolute plus...
CHT-RUBY Key Features
- Operating temperature: Junction temperature from -55°C to 225°C (other temperature range: contact marketing)
- Single or symmetrical supply operation (Operational Amplifier)
- Validated at 225°C for 1000 hours (and still on-going)
- Package: CSOIC16
- Fixed Reference Voltage: 5V
- Output voltage initial accuracy: ±2%
- Min dropout voltage: 2V @ 25mA
- Max. output current: 25mA @225°C
- Load capacitance: 100nF to 10 uF
- Stand-by current: 700µA typical