Description
The CHT-RUBY is a general-purpose triple operational amplifier combined with a bandgap voltage reference for applications with an operating temperature range of -55 to 225°C.
Features
- Operating temperature: Junction temperature from -55°C to 225°C (other temperature range: contact marketing).
- Single or symmetrical supply operation (Operational Amplifier).
- Validated at 225°C for 1000 hours (and still on-going).
- Package: CSOIC16
Voltage Reference:.
- Fixed Reference Voltage: 5V.
- Output voltage initial accuracy: ±2%.
- Min dropout voltage: 2V @ 25mA.
- Max. output current: 25mA @225°C.
- Load capacitance: 100nF to 10 uF.
- Stand-by curren.