Datasheet4U Logo Datasheet4U.com

4CM Datasheet Carbon Monoxide Citicel

Manufacturer: City Technology

Overview: Product Data Sheet 4CM CiTiceL® Carbon Monoxide (CO) Gas Sensor Part Number: 2112B2055R Product Datasheet 4CM Carbon Monoxide CiTiceL® Document Purpose The purpose of this document is to present the performance specification of the 4CM carbon monoxide sensor. This document should be used in conjunction with the 4CM Characterisation Note, Operating Principles (OP08) and the Product Safety Datasheet (PSDS 12.1). The data provided in this document are valid at 20°C, 50% RH and 1013 mBar for 3 months from the date of sensor manufacture. For guidance on sensor performance outside of these limits, please refer to the 4CM Characterisation Note. Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles OP08. Doc. Ref.: 4cm.indd Issue 3 ECN I4473 31st May 2016 Page 1 of 4 Web: .citytech. Email sales@citytech.

Datasheet Details

Part number 4CM
Manufacturer City Technology
File Size 730.09 KB
Description Carbon Monoxide CiTiceL
Datasheet 4CM-CityTechnology.pdf

Key Features

  • & Benefits:.
  • Fast response and recovery time.
  • Superior long-term performance at temperature and humidity extremes.
  • Meets sensor requirements described in AQ6205-2006 and EN45544-2000 Technical Specifications.

4CM Distributor