Datasheet4U Logo Datasheet4U.com

C0984-CL - Power Transformers

Key Features

  • very low secondary winding DCR and 1500 Vrms isolation from the primary and bias windings to the secondary. Coilcraft can also custom engineer a transformer to meet your specific requirements. For free evaluation samples, contact Coilcraft or visit www. coilcraft. com. Part   Inductance 2 DC R max (Ohms)   number1 Power min (µH) pri sec bias Leakage   inductance3 Turns ratio max (µH) pri : sec pri : bias C0984-CL_ 18 W 395 0.127 0.065 0.875 1.75 1 : 0.88 1 : .

📥 Download Datasheet

Datasheet Details

Part number C0984-CL
Manufacturer Coilcraft
File Size 110.54 KB
Description Power Transformers
Datasheet download datasheet C0984-CL Datasheet

Full PDF Text Transcription for C0984-CL (Reference)

Note: Below is a high-fidelity text extraction (approx. 800 characters) for C0984-CL. For precise diagrams, and layout, please refer to the original PDF.

Document 441 Power Transformer ForMaxim MAX5074 Isolated PWM Power IC The C0984-CL transformer is designed specifically for the Maxim MAX5074 isolated PWM power IC in a f...

View more extracted text
signed specifically for the Maxim MAX5074 isolated PWM power IC in a forward DCDC converter. It can be used in power supplies for IEEE 802.3af-compliant PoE applications, IP phones, WLAN Access-Points and a variety of other telecom applications with an input voltage range from 36 V to 72 V. This transformer features very low secondary winding DCR and 1500 Vrms isolation from the primary and bias windings to the secondary. Coilcraft can also custom engineer a transformer to meet your specific requirements. For free evaluation samples, contact Coilcraft or visit www.coilcraft.com.