Coto CS140
the CS140 offer high voltage switching and high load current. The CT140 utilizes a thru hole lead configuration, while the CS140 offers a surface mount option when the application requires it. Both relays are ideally suited to the needs of Test and Measurement, Solar, and Battery Management.FEATURES
u Contact Form: 1A u Load Voltage: 1500V Maximum u Operation LED Current: 5.0mA Maximum u Load Current: 45mA Maximum u On-Resistance: 180Ω Typical u Low Off-State Leakage Current: 10μA Maximum u I/O Breakdown Voltage: 3750Vrms Minimum u Suffix - H for I/O Breakdown Voltage: 5000Vrms Minimum CT140 0.358(9.1)Max. 0.047(1.2) DIMENSIONS in Inches (Millimeters) CS140 0.358(9.1)Max. 0.470(1.2) 0.051(1.3) 0.406(10.3)Max. 0.252(6.4) 0.010(0.25) 0.376(9.54)Max. 0.252(6.4) 0.310(7.87)Max. IDENTIFIES PIN #1 0.020(0.5) 0.162(4.1) 0.020(0.5) 0.118(3.0) 0.100(2.54) 0.200(5.08) TERMINAL IDENTIFICATION 654 123 (+) (-) 1: Anode (LED) 2: Cathode (LED) 3: NC 4,6: Drain (MOS FET) 5: Source (MOS FET) 0.020(0.5) 0.100(2.54) 0.010(0.25) IDENTIFIES PIN #1 0.200(5.08) 0.134(3.4) 0.154(3.9)Max. CONNECTIONS IF LOAD IF LOAD A Control bi-directional signal VL(AC or DC) IF LOAD VL(DC) B On-Resistance is 1/2 of A-connection IF VL(DC) C On-Resistance is 1/2 of B-connection LOAD VL(DC) 11032015 tel: (401) 943...