MP120D3
MP120D3 is Zero Cross0.02-3 Amps RMS12-140 Volts RMS3-32 Control - Volts DC manufactured by Crydom Corporation.
Series MP
- 4 Amps
- 120/240 Vac (AC Output)
- 60 Vdc (DC Output)
- SIP
- High Packaging Density
- patible w ith 5, 15 & 24 Volt Logic Systems
..
- Opto-Isolated 4000 Vrms
- Zero Voltage Sw itching (AC)
Available in 3Arms and 4Arms ratings, all are SPST-NO PC-mount relays that provide greater packaging density and patibility with pin out of Series 6 and OAC output modules. Internal snubber included for high dv/dt applications (AC). Manufactured in Crydom's ISO 9001 Certified facility for optimum product performance and reliability.
MODEL NUMBER
MP2 40D3
MP2 40D4
AC OUTPUT SPECIFICATIONS ➀
Operating Voltage Range (47-63 Hz) [Vrms] Load Current Range [Arms] Transient Overvoltage [Vpk] Max. Surge Current, (16.6ms) [Apk] Max. On-State Voltage Drop @ Rated Current [Vpk] Maximum I2 t for Fusing, (8.3 msec.) [A2sec] Max. Off-State Leakage Current @ Rated Voltage [m Arms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁ Max. Turn-On Time Max. Turn-Off Time Power Factor (Min.) with Max. Load
12-140 .02-3 400 90 1.6 36 5.0 200 1/2 Cycle 1/2 Cycle 0.5
24-280 .02-3 600 90 1.6 36 5.0 200 1/2 Cycle 1/2 Cycle 0.5
MPD CD3➂
24-280 .02-4 600 130 1.6 72 5.0 200 1/2 Cycle 1/2 Cycle 0.5
DC OUTPUT SPECIFICATIONS ➀
Operating Voltage Range [Vdc] Load Current Range [Adc] Max. Over Current (non-repetative) 1sec [A] Max. On-State Voltage Drop @ Rated Current [Vdc] Max. Turn-On time (Tdelay + Trise ) [µs] Max. Turn-Off time (Tdelay + Tfall ) [µs] Max. Off-State Leakage Current @ Rated Voltage [m A]
3-60 0.02-3.0 5.0 1.5 100 100 1.0
All M odels
INPUT SPECIFICATIONS ➀
Control Voltage Range [Vdc] Must Turn-On Voltage [Vdc] Must Turn-Off Voltage [Vdc] Typical Input Current @ 5Vdc [m A] Nominal Input Impedance [Ohms]
3-32 3.0 1.0 2.6
©2002 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
RS-343, paragraph...