SHM-50 - Sample Hold Amplifier

General Description

DATEL’s SHM-50 is a high-speed, highly accurate sample/hold designed for precision, high-speed analog signal processing applications.

Key Features

  • Small 8-pin DIP or SMT package.
  • 30ns typical acquisition time to ±0.01%, 40ns typical acquisition time to 0.005%.
  • 15ns typical sample-to-hold settling time to ±0.01%.
  • 100MHz small signal bandwidth.
  • 78dB feedthrough attenuation.
  • ±2 picoseconds aperture uncertainty.
  • 85mW typical, 135mW maximum power dissipation.

📥 Download Datasheet

Datasheet Details

Part number SHM-50
Manufacturer DATEL
File Size 172.04 KB
Description Sample Hold Amplifier
Datasheet download datasheet SHM-50 Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
SHM-50 Miniature, High-Speed, Complete ±0.05% Sample Hold Amplifiers SMT Package FEATURES „ Small 8-pin DIP or SMT package „ 30ns typical acquisition time to ±0.01%, 40ns typical acquisition time to 0.005% „ 15ns typical sample-to-hold settling time to ±0.01% „ 100MHz small signal bandwidth „ –78dB feedthrough attenuation „ ±2 picoseconds aperture uncertainty „ 85mW typical, 135mW maximum power dissipation GENERAL DESCRIPTION DATEL’s SHM-50 is a high-speed, highly accurate sample/hold designed for precision, high-speed analog signal processing applications. The SHM-50 features excellent dynamic specifications including a maximum acquisition time of only 40 nanoseconds for a 2V step to ±0.01%. Sample-to-hold settling time, to ±0.