MP03HBN330
FEATURES s Dual Device Module s Electrically Isolated Package s Pressure Contact Construction s International Standard Footprint s Alumina (non-toxic) Isolation Medium
APPLICATIONS s Motor Control s Controlled Rectifier Bridges s Heater Control s AC Phase Control
VOLTAGE RATINGS
Type Number
MP03XXX330-12 MP03XXX330-10 MP03XXX330-08
Repetitive Peak
Voltages VV
DRM RRM
Lower voltage grades available.
Conditions
Tvj = 130o C
IDRM
=
=
30m A
V &V =
V & V + 100V
RRM respectively
KEY PARAMETERS
VDRM ITSM IT(AV)(per arm) Visol
1200V 10600A 334A 3000V
DS4483-6.0 July 2002
Code HBT HBP HBN
Circuit Fig.1 Circuit diagrams
ORDERING INFORMATION
Order As: MP03HBT330-12 or MP03HBT330-10 or MP03HBT330-08 MP03HBP330-12 or MP03HBP330-10 or MP03HBP330-08 MP03HBN330-12 or MP03HBN330-10 or MP03HBN330-08 Note: When ordering, please use the plete part number.
Module type code: MP03. For further information see Package Details.
Fig. 2 Electrical...