Datasheet4U Logo Datasheet4U.com

SHM-49 - Sample Hold Amplifiers

General Description

DATEL’s SHM-49 is a high-speed, highly accurate sample/hold designed for precision, high-speed analog signal processing applications.

Key Features

  • Small 8-pin DIP or SMT package.
  • 200ns max. acquisition time to ±0.01%.
  • 100ns max. sample-to-hold settling time to ±0.01%.
  • 16MHz small signal bandwidth.
  • 74dB feedthrough attenuation.
  • ±25 picoseconds aperture uncertainty.
  • 415mW maximum power dissipation.

📥 Download Datasheet

Datasheet Details

Part number SHM-49
Manufacturer Datel
File Size 168.91 KB
Description Sample Hold Amplifiers
Datasheet download datasheet SHM-49 Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
SHM-49 Miniature, High-Speed, Complete ±0.05% Sample Hold Amplifiers SMT Package FEATURES „ Small 8-pin DIP or SMT package „ 200ns max. acquisition time to ±0.01% „ 100ns max. sample-to-hold settling time to ±0.01% „ 16MHz small signal bandwidth „ 74dB feedthrough attenuation „ ±25 picoseconds aperture uncertainty „ 415mW maximum power dissipation GENERAL DESCRIPTION DATEL’s SHM-49 is a high-speed, highly accurate sample/hold designed for precision, high-speed analog signal processing applications. The SHM-49 features excellent dynamic specifications including a maximum acquisition time of only 200 nanoseconds for a 10V step to ±0.01%. Sample-to-hold settling time, to ±0.01% accuracy, is 100 nanoseconds maximum with an aperture uncertainty of ±2 picoseconds.