Datasheet4U Logo Datasheet4U.com

MG5424 - X-Band Magnetron

Description

Compact, rugged, lightweight, fixed frequency magnetron, electrically the same as M5187.

Typical peak output power .

.

.

Heater voltage (see note 1) .

.

.

Features

  • accordance with information contained herein. MG5424, page 4 Printed.

📥 Download Datasheet

Datasheet preview – MG5424

Datasheet Details

Part number MG5424
Manufacturer E2V Technologies
File Size 133.79 KB
Description X-Band Magnetron
Datasheet download datasheet MG5424 Datasheet
Additional preview pages of the MG5424 datasheet.
Other Datasheets by E2V Technologies

Full PDF Text Transcription

Click to expand full text
www.DataSheet.co.kr E2V Technologies MG5424 X-Band Magnetron The data should be read in conjunction with the Magnetron Preamble. MAXIMUM AND MINIMUM RATINGS (Absolute values) These ratings cannot necessarily be used simultaneously, and no individual rating should be exceeded. Min Max Heater voltage (see note 1) . . . . . 5.7 6.9 V Heater starting current (peak) . . . . – 3.0 A Anode voltage (peak) . . . . . . . – 8.6 kV Anode current (peak) . . . . . . . 5.0 10 A Input power (mean) (see note 5) . . . – 100 W Pulse duration . . . . . . . . . – 2.0 ms Rate of rise of voltage pulse (see notes 6 and 7) . . . . . . . – 150 kV/ms VSWR at the output coupler . . . . – 1.5:1 Anode temperature . . . . . . .